Jetstream is an impulse fan designed for the ventilation of car parks and underground service areas, so as both to reduce levels of polluted air and to assist with the extraction of smoke in the event of a fire.

The fans use tunnel ventilation technology to eliminate the need for costly and bulky ductwork. Compared to ductwork systems, this may save car-parking spaces, reduce running costs and noise, and make the car park a lighter, less cluttered environment.

Colt
Headquarters: GB
Establishment date: 1931
Business area: UK
Assortment: Ventilators, Mechanical ventilators, Car park fans, Smoke and fire curtains, Evaporative coolers
Ask for product

Downloads

Product descritipion

Features and benefits

Wide variety of product options – Two non-flanged and three flanged versions to choose from, both unidirectional and reversible. The fan is suitable for either two speed or variable speed operation, depending on the application. Where the unit is inverter (variably) controlled, the amount of power consumed is reduced. Click on the Options tab above.

Certified performance - Jetstream has been exhaustively tested and certified to EN 12101-3 in accredited third party test laboratories and is CE marked.

Durable construction – Jetstream is manufactured from hot dipped galvanized casing with the option of a polyester powder coating to any RAL colour. Jetstream is manufactured to the ISO 9001 quality standard.

Low maintenance – With the additional advantage that there is no ductwork to clean.

Scheme design

Each car park is different and Colt will provide a scheme design to suit the exact requirements of the project. Colt car park ventilation systems can include one or more of the following elements:

  • Natural inlet through the entrance/exit ramps/fixed ventilation louvres.
  • Extract by a ducted system with dual fans discharging to atmosphere.
  • Air distribution and mixing within the car park by a network of Cyclone induction fans or Jetstream impulse fans.

As part of a designed scheme involving detection, controls and extract units, Jetstream adds momentum to the air to thrust it towards an extract point.

In general, for day to day operation the control system monitors the levels of pollutants within the car park and once a set point has been reached the system increases the ventilation rates. In a fire situation, once a signal from the fire alarm has been received, ventilation rates are increased.


Certification

All versions of Jetstream and their standard isolators fully meet the F300 time/ temperature classifications of EN 12101-3 (300°C continuous operation for one hour). Test Certificates are available on request.


Noise output

CIBSE Guide Volume A: 1999, Environmental Design, sets out a recommended maximum noise level of NR55 in car parks. Colt car park systems can be designed to achieve these noise levels if required.

Compliance

High velocity powered car park induction ventilation unit, for directing exhaust fumes (in day to day mode) and smoke in a controlled manner towards the main extract positions of a car park or underground service area.

Comprising an axial fan with inlet and discharge attenuators with outlet diffusers enabling flush fit with the underside of the car park ceiling.


Types

    Type 315J - 315mm diameter fan (uni-directional)
    Type 315J - 315mm diameter fan (reversible)
    Type 400J - 400mm diameter fan (uni-directional)
    Type 400J - 400mm diameter fan (reversible)

Options

    Single speed DOL motor suitable for inverter speed control, IP55 protection
    Two speed tap wound motor (full and half speed), IP55 protection

Motors supplied as standard with a IP65 lockable fire rated isolator or optionally with a fitted IP55 terminal box.
Finishes

    Pre-galvanised sheet (standard)
    Polyester powder coating to any RAL colour

Fire performance

    F300 - continuous operation for one hour at 300ºC

Sound emissions

CIBSE Guide Volume A: 1999, Environmental Design, sets out a recommended maximum noise level of NR55 in car parks. Colt car park systems can be designed to achieve these noise levels if required.
Compliance

The complete unit, including isolator, is rated at 300°C for 60 minutes, Class F300 to EN 12101-3 (2002). Jetstream is fully CE marked.

Ask for product
What is aeroventic?
  • What is aeroventic?

    Aeroventic is an international solution dedicated to HVACR industry. It has been designed to create an opportunity for both producers and distributors to present their business value and products worldwide. One system allowing for global reach.

  • Company profile

    Build your company value and present your competitive advantage.

    Share your catalogues, software selection programs and all business facts you consider important.

  • Product virtual showroom

    It is a great place to present all your products at once effortlessly.Each product is equipped with an option "Add to inquiry" for customer convenience. A customer sends an inquiry directly to you.

  • News & information channel

    Basically speaking, aeroventic is an equivalent of offline trade fair where you present your company and products, distribute catalogues, make contacts and develop your business.

What You Get with us?
Partners
What You Get with us?