• Fire Smoke Damper 0160 Advanced Air
  • Fire Smoke Damper 0160 Advanced Air
Prev Next
Fire Smoke Damper 0160 Advanced Air

Our smoke dampers are used to manage smoke only, whilst our fire smoke dampers also manage fire and are designed to close when the temperature reaches 74°c. The High temperature damper operates continuously at 300°c for upto 2 hours.

All our dampers are designed for application in ventilation and air conditioning systems where the air way is normally clean and the temperature and humidity are controlled. They have been independently tested and witnessed by the Building Research Establishment (BRE).

Advanced Air
Profile: Manufacturer
Headquarters: GB
Assortment: Fan coils, Diffusers, Grilles, Dampers
Ask for product

Downloads

Product descritipion

Fire Smoke Damper 0160

The 0160 series curtain fire dampers are designed to stop the spread of fire through ductwork, walls and floors in ventilation systems. When the fusible link reaches elevated temperature, it releases interlocking blades closing the damper by locking into the blade ramp sealing the damper closed. With the introduction of Construction Product Regulation on the 1st July 2013 all fire dampers are required to meet the product standard BS EN 15650. To achieve this standard the damper has to be tested to BS EN 1366-2 dynamic fire test. The dampers are then classified to BS EN
13501-3 that clearly states the integrity of the damper also in the way that damper was installed in the furnace. The standard also now included testing of fusible link to ISO 10294-4 that comprises of a dynamic release and holding tests. The biggest change in the current Building regulations Part B and
Section 7 and the CPR is fire dampers have to be CE marked and that the dampers must be installed as tested. The maximum single section unit tested was 1000mm x 1000mm for both the HEVAC and AFS frame. Sizes above the maximum will be supplied as multi-section and are notCE labelled due to the current issues with the extended fields of application that we will shortly have an answer on.

Construction Product Regulation

To meet the requirements of the Construction Products Regulation 1st July 2013 Advanced Air fire dampers meet the requirements of the Product
Standard BS EN 15650 with a classification under BS EN 13501-3 as stated in our Declaration Of Performance that has been assessed by the notified
certification body BRE who have issued a Certificate of Consistency of Performance No: 0832-CPRP0004.

 

Ask for product
What is aeroventic?
  • What is aeroventic?

    Aeroventic is an international solution dedicated to HVACR industry. It has been designed to create an opportunity for both producers and distributors to present their business value and products worldwide. One system allowing for global reach.

  • Company profile

    Build your company value and present your competitive advantage.

    Share your catalogues, software selection programs and all business facts you consider important.

  • Product virtual showroom

    It is a great place to present all your products at once effortlessly.Each product is equipped with an option "Add to inquiry" for customer convenience. A customer sends an inquiry directly to you.

  • News & information channel

    Basically speaking, aeroventic is an equivalent of offline trade fair where you present your company and products, distribute catalogues, make contacts and develop your business.

What You Get with us?
Partners
What You Get with us?